Jackery
Simple operation and a well-known name, which matters for a medical purchase.
Buying scenario
A CPAP is a nightly, non-negotiable load. Sizing is straightforward once you know whether the humidifier and heated tube are in use — and it changes the capacity you need by more than double.
The short version
Who: CPAP and BiPAP users who need guaranteed overnight power
The spec that decides it: Capacity (Wh) — The whole decision. Humidifier and heated tube can double or triple draw.
What they get wrong: Sizing for the CPAP without the humidifier, then using the humidifier
In priority order. These are not the specs with the biggest numbers — they are the ones that change whether the product works for this buyer.
| Spec | Why it decides the purchase |
|---|---|
| Capacity (Wh) | The whole decision. Humidifier and heated tube can double or triple draw. |
| Continuous AC output | Modest for a CPAP, but confirm the device tolerates the inverter waveform. |
| DC output option | Running a CPAP from 12V DC instead of AC can extend runtime substantially. |
| Recharge speed | You need it full again before the next night. |
| Pass-through charging | Keeps the unit topped up while it stays connected. |
Simple operation and a well-known name, which matters for a medical purchase.
UPS behaviour and app visibility on state of charge overnight.
Quiet operation and a clear app for checking remaining runtime.
Long-standing 12V output support and DC accessories.
| Band | Capacity | What that buys you |
|---|---|---|
| One night, no humidifier | 300–500 Wh | Typical CPAP draw only |
| One night, with humidifier | 600–1000 Wh | Roughly doubles the load |
| Two nights plus essentials | 1000–2000 Wh | Margin for a second night and other devices |
Because medical & cpap backup buyers are buying longest service life more than anything else, these shortlists are that ranking filtered to each capacity band above. They are computed from the same verified specs as the rest of the site, not picked by hand.
Typical CPAP draw only
| Model | Capacity | AC output | Weight | $/Wh | List price |
|---|---|---|---|---|---|
| Yeti 500 Goal Zero | 499 Wh | 500 W | 16.1 lb | $1.00 | $499.95 |
| AC50B BLUETTI | 448 Wh | 700 W | 14.8 lb | $1.11 | $499 |
| Yeti 400 Lithium Goal Zero | 428 Wh | 300 W | 16.3 lb | $1.40 | $599.95 |
Roughly doubles the load
| Model | Capacity | AC output | Weight | $/Wh | List price |
|---|---|---|---|---|---|
| Yeti 1000 Goal Zero | 998 Wh | 2 kW | 35.3 lb | $1.20 | $1,199.95 |
| Explorer 600 v2 Jackery | 640 Wh | 500 W | 14.1 lb | $0.78 | $499 |
| F1000LFP PECRON | 960 Wh | 1.5 kW | 23.9 lb | $0.42 | $399 |
Margin for a second night and other devices
| Model | Capacity | AC output | Weight | $/Wh | List price |
|---|---|---|---|---|---|
| Explorer 1500 v2 Jackery | 1.54 kWh | 2 kW | 32.0 lb | $0.62 | $949 |
| Explorer 1500 Ultra Jackery | 1.54 kWh | 1.8 kW | 38.6 lb | $0.78 | $1,199 |
| Yeti 1500 Goal Zero | 1.50 kWh | 2 kW | 52.8 lb | $1.00 | $1,499.95 |
Runtime assumes 85% inverter efficiency and 90% usable depth of discharge, so a 1,000 Wh unit provides roughly 765 Wh of usable AC energy. Vendor figures differ; adjust for your own unit.
| Load | Typical draw | 500 Wh | 1,000 Wh | 2,000 Wh | 4,000 Wh |
|---|---|---|---|---|---|
| CPAP, no humidifier, no heated tube Typical average draw | 30 W | 13 h | 26 h | 51 h | 102 h |
| CPAP with humidifier Average over a night | 60 W | 6.4 h | 13 h | 26 h | 51 h |
| CPAP with humidifier and heated tube Highest common configuration | 90 W | 4.3 h | 8.5 h | 17 h | 34 h |
| Oxygen concentrator (portable) Varies widely by model | 120 W | 3.2 h | 6.4 h | 13 h | 26 h |