The short version

Who: CPAP and BiPAP users who need guaranteed overnight power

The spec that decides it: Capacity (Wh) The whole decision. Humidifier and heated tube can double or triple draw.

What they get wrong: Sizing for the CPAP without the humidifier, then using the humidifier

Who is buying

Why they are buying

What it will actually run

The specs that decide this purchase

In priority order. These are not the specs with the biggest numbers — they are the ones that change whether the product works for this buyer.

SpecWhy it decides the purchase
Capacity (Wh)The whole decision. Humidifier and heated tube can double or triple draw.
Continuous AC outputModest for a CPAP, but confirm the device tolerates the inverter waveform.
DC output optionRunning a CPAP from 12V DC instead of AC can extend runtime substantially.
Recharge speedYou need it full again before the next night.
Pass-through chargingKeeps the unit topped up while it stays connected.

What this buyer pays extra for

Who solves it best

All brand profiles →
Brand

Jackery

Simple operation and a well-known name, which matters for a medical purchase.

12 models tracked

Brand

EcoFlow

UPS behaviour and app visibility on state of charge overnight.

12 models tracked

Brand

Anker SOLIX

Quiet operation and a clear app for checking remaining runtime.

10 models tracked

Brand

Goal Zero

Long-standing 12V output support and DC accessories.

12 models tracked

How much capacity you need

BandCapacityWhat that buys you
One night, no humidifier300–500 WhTypical CPAP draw only
One night, with humidifier600–1000 WhRoughly doubles the load
Two nights plus essentials1000–2000 WhMargin for a second night and other devices

Model shortlists, computed from the dataset

Full Longest service life ranking →

Because medical & cpap backup buyers are buying longest service life more than anything else, these shortlists are that ranking filtered to each capacity band above. They are computed from the same verified specs as the rest of the site, not picked by hand.

One night, no humidifier (300–500 Wh)

Typical CPAP draw only

ModelCapacityAC outputWeight$/WhList price
Yeti 500
Goal Zero
499 Wh500 W16.1 lb$1.00$499.95
AC50B
BLUETTI
448 Wh700 W14.8 lb$1.11$499
Yeti 400 Lithium
Goal Zero
428 Wh300 W16.3 lb$1.40$599.95

One night, with humidifier (600–1000 Wh)

Roughly doubles the load

ModelCapacityAC outputWeight$/WhList price
Yeti 1000
Goal Zero
998 Wh2 kW35.3 lb$1.20$1,199.95
Explorer 600 v2
Jackery
640 Wh500 W14.1 lb$0.78$499
F1000LFP
PECRON
960 Wh1.5 kW23.9 lb$0.42$399

Two nights plus essentials (1000–2000 Wh)

Margin for a second night and other devices

ModelCapacityAC outputWeight$/WhList price
Explorer 1500 v2
Jackery
1.54 kWh2 kW32.0 lb$0.62$949
Explorer 1500 Ultra
Jackery
1.54 kWh1.8 kW38.6 lb$0.78$1,199
Yeti 1500
Goal Zero
1.50 kWh2 kW52.8 lb$1.00$1,499.95

Reference runtimes

Runtime assumes 85% inverter efficiency and 90% usable depth of discharge, so a 1,000 Wh unit provides roughly 765 Wh of usable AC energy. Vendor figures differ; adjust for your own unit.

LoadTypical draw500 Wh1,000 Wh2,000 Wh4,000 Wh
CPAP, no humidifier, no heated tube
Typical average draw
30 W13 h26 h51 h102 h
CPAP with humidifier
Average over a night
60 W6.4 h13 h26 h51 h
CPAP with humidifier and heated tube
Highest common configuration
90 W4.3 h8.5 h17 h34 h
Oxygen concentrator (portable)
Varies widely by model
120 W3.2 h6.4 h13 h26 h

Mistakes to avoid